Author : Orlando F., Graziano D., Foiani S., Dellavia C., Danilo A. Di Stefano

A slow-resorbing equine bone substitute to augment the alveolar ridge

This case report describes the fixed rehabilitation of the lower left arch in a 60-year old patient following an horizontal GBR procedure by means of a customized titanium mesh and a new slow resorption bone substitute of equine origin. By means of CBCT, endoral x-ray and histological analyses, the quality of the bone regeneration obtained is described.

PRODUCTS USED: OSTEOPLANT CALCITOS, BIOCOLLAGEN MEMBRANE 